7” Color TFT Display Patient Monitor 6 Parameters +NIBP +SPO2 +ECG +TEMP +HR +RESP

  Contact Vendor
Compare

$695.00

Compare

Description

7” Color TFT Display Patient Monitor 6 Parameters +NIBP +SPO2 +ECG +TEMP +HR +RESP

 

Features & Benefits:
1. 7” color TFT display, high resolution 800×480 dpi;
2. Separated para board: ECG, NIBP, SpO2 board;
3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
4. Real time S-T segment analysis, and ARR analysis;
5. SpO2 Pitch Tone Variation and Drug Dose Calculation;
6. Parameter waveform and characters color selectable
7. Multi and unique display: Standard, Large font, Trend Coexis, OxyCRG dynamic
8. Standby mode for Energy saving and suspend monitoring;
9. 7-lead ECG waveforms display in phase;
10. Capture dynamic waveforms;
11. Built-in rechargeable lithium battery, and battery volume checking.
12. Efficient resistance to interference of defibrillator and HF knife;
13. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
14. TCP/IP networking platform enable abundant future upgrade
15. Complete and flexible mounting solution for transportation and in-patient monitoring

Standard parameters:

  • 5-lead ECG, RESP, HR, NIBP, SPO2(F-5), 1-TEMP, PR;
  • Optional: Touch Screen, Et CO2, SpO2(F-6)
  • Performance Specifications
    Display: 7’’color TFT
    Rolling and refreshing waveform display
    Resolution: 800×480
    Multi display selectable including:
    Large-font display
    Trend coexist display
    OxyCRG dynamic view display.
    Bed-to-bed view display
    Trace: 4 waveforms
    Sweep speed:6.25mm/s, 12.5mm/s,25mm/s,50mm/s
    Indicator: Power/battery indicator light
    QRS beep and alarm sound
    Battery: Rechargeable lead acid cell, 12v/4AH
    Max.24 hour for charging, 4 hours for continue working
    Trend: Parameter graphic and tabular trends:
    5s/piece, 8 hours;
    1min/piece,168 hours(24hour×7days)
    5min/piece, 1000 hours.
    Storage: NIBP:1000 groups
    Alarm:200 groups
    Full disclosure waveforms: 3600S
    Alarm: User-adjustable High, Medium and Low limits 3-level Audible and visual
    alarm
    Networking: Connected to central monitoring system
    TCP/IP netting platform
    Recorder: Build-in, thermal array
    Plethysmogram caveform:2 channels
    Record mode: manual, on alarm, time-defined
    Recording width: 50mm
    Printing speed: 50mm/s
    Recording type: Frozen waveform record
    NIBP recall record
    Trend table record
    Alarm record
    Fixed -time record
    Standard Parameter:
  • ECG:
    Lead mode: 5 –lead(R,L,F,N,C)
    Lead selection : I,II,III,avR,avL,avF,V
    Waveform: 4 channels
    Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
    Sweep speed: 6.25mm/s; 12.5mm/s;25mm/s;50mm/s
    Heart rate range: Adult: 15~300bpm; Neonate:/pediatric:15~350bpm
    Accuracy: +1bpm or +1%,whichecer is greater
    Resolution: 1bpm
    Filter: surgery mode:1~20Hz
    monitor model:0.5~40Hz
    Diagnostic mode:0.05~130Hz
    Scaling signal: 1mv,+3%
    Protection: withstand 4000VAC/50 voltage isolation against electrosurgical
    interference and defibrillation
    Alarm range: 15~350bpm
    S-T segment detecton:
    Measurement range: 2.0mV~+2.0mV
    Alarm Range: -2.0mV~ +2.0mV
    Accuracy: -0.8mV ~+0.8Mv
    Error: +0.02Mv
    Arrhythmia analysis: YES
  • SPO2
    Measurement range: 0~100%
    Resolution: 1%
    Accuracy: +2%(70-100%);0-69% unspecified
    Alarm range 0~100%
    Pluse Rate: range:20~300bpm
    Resolution:1bpm
    Error:+1bpm or +2%,whichever is greater
  • NIBP
    Method: Digital Automatic oscillometric
    Operation mode : Manual/Automatic/continuous
    Auto measurement time: Adjustable(1~480min)
    Measurement Unit: mmHg/Kpa selectable
    Measurement types: Systolic, Diastolic, Mean
    Measurement tange:
    Range of Systolic pressure: Adult: 40~270mmHg
    Pediatric: 40~220mmHg
    Neonate: 40~135mmHg
    Range of mean pressure: Adult: 20~235mmHg
    Pediatric: 20~165mmHg
    Neonate: 20~110mmHg
    Range of diastolic pressure: Adult: 10~215mmHg
    Pediatric: 10~150mmHg
    Neonate :10~100mmHg
    Over-pressure protection: Double safety protection
    Resolution: 1 mmHg
    Alarm: Systolic.Diastolic,Mean
  • RESPIRATION
    Method: Thoracic impedance
    Measurement range: Adult:7~120rpm;
    Neonate/Pediatric:7~150rpm
    Apnea alarm: YES,10~40s
    Resolution: 1rpm
    Accuracy: +2rpm
  • TEMPERATURE
    Compatible probe: YSI or CYF
    Measurement range: 5~50℃
    Resolution : 0.1℃
    Accuracy: +0.1℃
    Refreshing time: about 1
    Average measuring time: <10s